Error While Connecting To CRM Online Using Kingsway SSIS Connector

Issue:

I have recently got this error when i was preparing an SSIS package for Dynamics CRM 365 Online and used Kingsway SSIS connector.

Kingsway1

Resolution:

After digging in further this error is mainly caused by the request and reponse timings,So, when i checked i found out my system time was somehow 5 minutes ahead of the current time, hence the request going to CRM server was of a future time and hence this error showed up.

All i had to do is fix my system time. Sometimes even if your system time is fine, you might still get the error, In that scenario too try to change the time as 5 minutes less.

 

Once i did that -my organisation name popped up without any issue.
kingsway2.png

 

Hope this helps!

Cheers!

 

Advertisement

An unsecured or incorrectly secured fault was received from the other party

Issue :

Recently i have encountered this error when i was trying to connect to Dynamics CRM 365 online.

error1.PNG

 

I digged in further and found a post where couple of suggestions were mentioned :

https://community.dynamics.com/crm/f/117/t/204264

Solution : It was to do with my system settings(Time) – my system time was ahead of the server time. which means the request was going to server with a future time. 

hence i have changed the time in my system clock to be 5 minutes less. Which indeed worked.

 

I hope this helps!